There are two essential components to all telephone calls. The first, and most obvious, is the actual content—our voices, faxes, modem data, etc. The second is the information that instructs telephone exchanges to establish connections and route the “content” to an appropriate destination. Telephony signaling is concerned with the creation of standards for the latter to achieve the former. These standards are known as protocols. SS7 or Signaling System Number 7 is simply another set of protocols that describe a means of communication between telephone switches in public telephone networks. They have been created and controlled by various bodies around the world, which leads to some specific local variations, but the principal organization with responsibility for their administration is the International Telecommunications Union or ITU-T.
Signalling System Number 7 (SS#7 or C7) is the protocol used by the telephone companies for interoffice signalling. In the past, in-band signalling techniques were used on interoffice trunks. This method of signalling used the same physical path for both the call-control signalling and the actual connected call. This method of signalling is inefficient and is rapidly being replaced by out-of-band or common-channel signalling techniques.
SS7 Call Flow
Signalling System Number 7 (SS#7 or C7) is the protocol used by the telephone companies for interoffice signalling. In the past, in-band signalling techniques were used on interoffice trunks. This method of signalling used the same physical path for both the call-control signalling and the actual connected call. This method of signalling is inefficient and is rapidly being replaced by out-of-band or common-channel signalling techniques.
SS7 Call Flow
SS7 protocol suite
The SS7 protocol stack borrows partially from the OSI Model of a packetized digital protocol stack.
SS7 Protocol layers:
The SS7 network is an interconnected set of network elements that is used to exchange messages in support of telecommunications functions. The SS7 protocol is designed to both facilitate these functions and to maintain the network over which they are provided. Like most modern protocols, the SS7 protocol is layered.
Physical Layer (MTP-1) This defines the physical and electrical characteristics of the signaling links of the SS7 network. Signaling links utilize DS–0 channels and carry raw signaling data at a rate of 56 kbps or 64 kbps (56 kbps is the more common implementation). Message Transfer Part—Level 2 (MTP-2) The level 2 portion of the message transfer part (MTP Level 2) provides link-layer functionality. It ensures that the two end points of a signaling link can reliably exchange signaling messages. It incorporates such capabilities as error checking, flow control, and sequence checking. Message Transfer Part—Level 3 (MTP-3) The level 3 portion of the message transfer part (MTP Level 3) extends the functionality provided by MTP level 2 to provide network layer functionality. It ensures that messages can be delivered between signaling points across the SS7 network regardless of whether they are directly connected. It includes such capabilities as node addressing, routing, alternate routing, and congestion control. |
Signaling Connection Control Part (SCCP)
The signaling connection control part (SCCP) provides two major functions that are lacking in the MTP. The first of these is the capability to address applications within a signaling point. The MTP can only receive and deliver messages from a node as a whole; it does not deal with software applications within a node.
While MTP network-management messages and basic call-setup messages are addressed to a node as a whole, other messages are used by separate applications (referred to as subsystems) within a node. Examples of subsystems are 800 call processing, calling-card processing, advanced intelligent network (AIN), and custom local-area signaling services (CLASS) services (e.g., repeat dialing and call return). The SCCP allows these subsystems to be addressed explicitly.
ISDN User Part (ISUP)
ISUP user part defines the messages and protocol used in the establishment and tear down of voice and data calls over the public switched network (PSN), and to manage the trunk network on which they rely. Despite its name, ISUP is used for both ISDN and non–ISDN calls. In the North American version of SS7, ISUP messages rely exclusively on MTP to transport messages between concerned nodes.
Transaction Capabilities Application Part (TCAP)
TCAP defines the messages and protocol used to communicate between applications (deployed as subsystems) in nodes. It is used for database services such as calling card, 800, and AIN as well as switch-to-switch services including repeat dialing and call return. Because TCAP messages must be delivered to individual applications within the nodes they address, they use the SCCP for transport.
Operations, Maintenance, and Administration Part (OMAP)
OMAP defines messages and protocol designed to assist administrators of the SS7 network. To date, the most fully developed and deployed of these capabilities are procedures for validating network routing tables and for diagnosing link troubles. OMAP includes messages that use both the MTP and SCCP for routing.